Relining old chimneys
![]() |
Our exclusive Multiflex “Class 1” flexible stainless steel multifuel flue liners are designed to provide a quick and economical solution for improving the safety and efficiency of old chimneys. There are many situations where Multiflex is the best choice for solving common chimney problems. Continual development using improvements in modern materials and advances in technology ensures that Multiflex leads the market in terms of quality and performance. Multiflex is the unique name for our exclusive range of liners that are recognised for their high quality, leading specification and performance that many try to copy. Beware of any imitations that attempt to use the Multiflex name, which is a Registered Trademark. |
![]() |
If your chimney is leakingAfter many years use old, and particularly unlined chimneys can create many problems. Over time hot smoke, tars and acids eat into the chimney walls and erode mortar joints causing staining to the exterior stone or brickwork, and leakage of dangerous fumes into the property. Multiflex protects old chimneys against deterioration and leakage by providing a new gastight flue liner that withstands high temperatures and minimises the risk of tar deposits. If you have problems with smoky firesLarge chimneys with oversized, uneven or damp flues are very inefficient and usually produce poor up draught causing smoke to blow back into the room. The Multiflex liner provides a smooth and sealed flue that warms quickly to create a strong updraught, allowing stoves and fires to operate efficiently. Opening up an old fireplace or installing a new fireAs many old chimneys were built without flue liners and risk leakage it is always prudent to have a new liner fitted. Indeed, most stove and fire manufacturers require that the chimney has a suitable flue liner of the correct size and specification to ensure safe and efficient operation of the fire or stove. Multiflex is available in wide choice of sizes complete with fittings for easy connection to stoves and fires. The liners are specially designed for quick installation with the minimum of disruption, and their flexibility can cope with bends of up to 45 degree and typical “offset” Victorian chimneys. |
High grade specification and materialsMultiflex liners have a robust double-skin construction for use with multifuel burning stoves, fires or boilers. The inner wall is designed to provide a smooth gas tight flue for the safe and efficient passage of flue gases. The outer skin has a durable corrugated construction to allow maximum flexibility. The liners are listed by HETAS for use with solid fuel and are covered by CSTB testing approval to comply with UK Building Regulations. The liners have a performance designation of the liners as defined by European Standard BS EN 1443 is T450 N2 S D3.There are two types of Multiflex liner.
Multiflex 316. Made from the 316 grade stainless steel for use with open fires, multifuel or wood burning stoves, and appliances burning gas or oil. Multiflex 904L. Made entirely from high-grade 904L stainless steel that has significantly increased resistance against corrosion. Designed for use with coal or solid fuel burning appliances, and for installations where a higher specification of liner is required. A typical Multiflex liner installation with a stove and range of fittings: ![]() |
Fittings
![]() |
FC - Top Fixing ClampSecures and supports the liner at the top of the chimney. |
||||||||||||||||||||||||
![]() |
CP - Top Closing PlateUsed to close off the gap around the liner at the top of the chimney. |
||||||||||||||||||||||||
![]() |
BS - Bottom Support Bracket Provides lateral restraint to the base of the liner. |
||||||||||||||||||||||||
![]() |
BSR - Bottom Support Bracket Supports the base of the liner when it is insulated with the
RW insulation |
||||||||||||||||||||||||
![]() |
MA - Adaptor Connects the liner to a flue pipe of the same diameter. |
||||||||||||||||||||||||
![]() |
MR - Reducer Connects the liner to a flue pipe of smaller diameter. (See the table below for spigot sizes.) |
||||||||||||||||||||||||
![]() |
MC - ConnectorUsed for connection of the liner to special flue pipes. Has a socket at both ends. |
||||||||||||||||||||||||
![]() |
GA - Gather Adaptor Secured and sealed into the masonry gather above an open fire,
this adaptor |
||||||||||||||||||||||||
![]() |
RW - Rockwool Insulation MatUsed to insulate liners in large chimneys. The mat is 30mm thick with galvanized wire mesh backing and supplied in 1metre x 5metre rolls. (See table for coverage.) |
||||||||||||||||||||||||
![]() |
MFS - Inner sleeve insertSlides into the top end of the liner to cover the cut edges |
||||||||||||||||||||||||
The liners are available in cut lengths to the nearest metre or in full coils in the following diameters:-
Download a pdf version of the full colour Multiflex brochure Download a black and white pdf of
the Multiflex installation instructions |
|||||||||||||||||||||||||
![]() |
Isokern Pumice LinersThis is the original pumice flue liner system with over 50 years proven use in Scandinavia and has approvals from many different countries, including British Board of Agrément certification. Lightweight and easy to handle these liners are lowered down the chimney then surrounded by an insulating backfill. With probably the largest range of flue sizes from 130mm (5 inch) to 1000mm (40 inch) diameter, Isokern pumice flue liners are an ideal choice for relining both domestic and commercial chimneys |
Choosing a chimney relining systemAs each chimney is different and the choice of systems is so wide, please contact us to talk through the options. |